Endress+Hauser

Collection by Ali H

143 
Pins
 • 
171 
Followers
Ali H
Endress+Hauser Canada's booth at the 2015 Manitoba Water and Wastewater Association Annual Conference and Tradeshow Endress Hauser, Process Engineering, Teamwork, Conference, Canada, Water, Gripe Water

Endress+Hauser Canada's booth at the 2015 Manitoba Water and Wastewater Association Annual Conference and Tradeshow

Deltatop DO61W  Differential pressure flow measurement with orifices and Deltabar differential pressure transmitter         Your benefits    selectable according to the application:  - operational compact version  - modular remote version   optimized for minimum pressure loss, highest accuracy and maximum measuring dynamics   measuring range of the Deltabar differential pressure transmitter adjusted on delivery   measurement method globally standardized according to ISO 5167 Endress Hauser, Temperature Measurement, Compact, Flow, Remote, Delivery, Range, Cookers, Pilot

Flow, level, liquid analysis, pressure, temperature measurement, software and system products

Deltatop DO61W Differential pressure flow measurement with orifices and Deltabar differential pressure transmitter Your benefits selectable according to the application: - operational compact version - modular remote version optimized for minimum pressure loss, highest accuracy and maximum measuring dynamics measuring range of the Deltabar differential pressure transmitter adjusted on delivery measurement method globally standardized according to ISO 5167

Deltatop DO61W  Differential pressure flow measurement with orifices and Deltabar differential pressure transmitter         Your benefits    selectable according to the application:  - operational compact version  - modular remote version   optimized for minimum pressure loss, highest accuracy and maximum measuring dynamics   measuring range of the Deltabar differential pressure transmitter adjusted on delivery   measurement method globally standardized according to ISO 5167 Endress Hauser, Temperature Measurement, Compact, Flow, Remote, Delivery, Range, Cookers, Pilot

Flow, level, liquid analysis, pressure, temperature measurement, software and system products

Deltatop DO61W Differential pressure flow measurement with orifices and Deltabar differential pressure transmitter Your benefits selectable according to the application: - operational compact version - modular remote version optimized for minimum pressure loss, highest accuracy and maximum measuring dynamics measuring range of the Deltabar differential pressure transmitter adjusted on delivery measurement method globally standardized according to ISO 5167

Micropilot FMR51  Level measurement in liquids         Your benefits    Reliable measurement even for changing product and process conditions    Integrated data memory for high availability    Intuitive operating menu in national languages for easy commissioning    Simple integration into control or asset management systems    Exact diagnostic and process information to assist fast decisions    International approvals for use in hazardous areas    5-point linearity protocol Endress Hauser, National Language, Temperature Measurement, Asset Management, Software, Conditioner, Industrial, Languages, Menu

Flow, level, liquid analysis, pressure, temperature measurement, software and system products

Micropilot FMR51 Level measurement in liquids Your benefits Reliable measurement even for changing product and process conditions Integrated data memory for high availability Intuitive operating menu in national languages for easy commissioning Simple integration into control or asset management systems Exact diagnostic and process information to assist fast decisions International approvals for use in hazardous areas 5-point linearity protocol

Deltatop DO62C  Differential pressure flow measurement with orifices and Deltabar differential pressure transmitter         Your benefits    selectable according to the application  - operational compact version  - modular remote version   optimized for minimum pressure loss, highest accuracy and maximum measuring dynamics   measuring range of the Deltabar differential pressure transmitter adjusted on delivery   measurement method globally standardized according to ISO 5167 Endress Hauser, Temperature Measurement, Compact, Flow, Remote, Delivery, Range, Cookers, Pilot

Flow, level, liquid analysis, pressure, temperature measurement, software and system products

Deltatop DO62C Differential pressure flow measurement with orifices and Deltabar differential pressure transmitter Your benefits selectable according to the application - operational compact version - modular remote version optimized for minimum pressure loss, highest accuracy and maximum measuring dynamics measuring range of the Deltabar differential pressure transmitter adjusted on delivery measurement method globally standardized according to ISO 5167

Deltatop DO62C  Differential pressure flow measurement with orifices and Deltabar differential pressure transmitter         Your benefits    selectable according to the application  - operational compact version  - modular remote version   optimized for minimum pressure loss, highest accuracy and maximum measuring dynamics   measuring range of the Deltabar differential pressure transmitter adjusted on delivery   measurement method globally standardized according to ISO 5167 Endress Hauser, Temperature Measurement, Compact, Flow, Remote, Delivery, Range, Cookers, Pilot

Flow, level, liquid analysis, pressure, temperature measurement, software and system products

Deltatop DO62C Differential pressure flow measurement with orifices and Deltabar differential pressure transmitter Your benefits selectable according to the application - operational compact version - modular remote version optimized for minimum pressure loss, highest accuracy and maximum measuring dynamics measuring range of the Deltabar differential pressure transmitter adjusted on delivery measurement method globally standardized according to ISO 5167

Micropilot FMR51  Level measurement in liquids         Your benefits    Reliable measurement even for changing product and process conditions    Integrated data memory for high availability    Intuitive operating menu in national languages for easy commissioning    Simple integration into control or asset management systems    Exact diagnostic and process information to assist fast decisions    International approvals for use in hazardous areas    5-point linearity protocol Endress Hauser, National Language, Temperature Measurement, Asset Management, Software, Conditioner, Industrial, Languages, Menu

Flow, level, liquid analysis, pressure, temperature measurement, software and system products

Micropilot FMR51 Level measurement in liquids Your benefits Reliable measurement even for changing product and process conditions Integrated data memory for high availability Intuitive operating menu in national languages for easy commissioning Simple integration into control or asset management systems Exact diagnostic and process information to assist fast decisions International approvals for use in hazardous areas 5-point linearity protocol

Deltatop DO64P  Differential pressure flow measurement with orifices and Deltabar differential pressure transmitter         Your benefits    selectable according to the application:  - operational compact version  - modular remote version   optimized for minimum pressure loss, highest accuracy and maximum measuring dynamics   measuring range of the Deltabar differential pressure transmitter adjusted on delivery   measurement method globally standardized according to ISO 5167 Endress Hauser, Temperature Measurement, Compact, Flow, Remote, Delivery, Range, Cookers, Pilot

Flow, level, liquid analysis, pressure, temperature measurement, software and system products

Deltatop DO64P Differential pressure flow measurement with orifices and Deltabar differential pressure transmitter Your benefits selectable according to the application: - operational compact version - modular remote version optimized for minimum pressure loss, highest accuracy and maximum measuring dynamics measuring range of the Deltabar differential pressure transmitter adjusted on delivery measurement method globally standardized according to ISO 5167

Deltatop DO64P  Differential pressure flow measurement with orifices and Deltabar differential pressure transmitter         Your benefits    selectable according to the application:  - operational compact version  - modular remote version   optimized for minimum pressure loss, highest accuracy and maximum measuring dynamics   measuring range of the Deltabar differential pressure transmitter adjusted on delivery   measurement method globally standardized according to ISO 5167 Endress Hauser, Temperature Measurement, Compact, Flow, Remote, Delivery, Range, Cookers, Pilot

Flow, level, liquid analysis, pressure, temperature measurement, software and system products

Deltatop DO64P Differential pressure flow measurement with orifices and Deltabar differential pressure transmitter Your benefits selectable according to the application: - operational compact version - modular remote version optimized for minimum pressure loss, highest accuracy and maximum measuring dynamics measuring range of the Deltabar differential pressure transmitter adjusted on delivery measurement method globally standardized according to ISO 5167

2013 New Price E+H Ultrasonic flowmeter Prosonic Flow Deltatop Endress Hauser, Temperature Measurement, Flow, Compact, Remote, Delivery, Range, Cookers, Pilot

Flow, level, liquid analysis, pressure, temperature measurement, software and system products

Deltatop DO63C Differential pressure flow measurement with orifices and Deltabar differential pressure transmitter Your benefits selectable according to the application: - operational compact version - modular remote version optimized for minimum pressure loss, highest accuracy and maximum measuring dynamics measuring range of the Deltabar differential pressure transmitter adjusted on delivery measurement method globally standardized according to ISO 5167

Micropilot M FMR230  Continuous and non-contact level measurement.    Cost-effective 4 to 20 mA 2-wire technology. Suitable for hazardous locations.    Benefits:  2-wire technology, real alternative to differential pressure, floats and displacers.  2-wire technology reduces wiring costs and allows easy implementation into existing systems.   Non-contact measurement:   Frequency range - in the C-band.   HART or PROFIBUS PA respectively FOUNDATION Fieldbus protocol.   High temperatures: Endress Hauser, Temperature Measurement, Wells, Monitor, Foundation, Alternative, Wire, Range, Technology

Flow, level, liquid analysis, pressure, temperature measurement, software and system products

Micropilot M FMR230 Continuous and non-contact level measurement. Cost-effective 4 to 20 mA 2-wire technology. Suitable for hazardous locations. Benefits: 2-wire technology, real alternative to differential pressure, floats and displacers. 2-wire technology reduces wiring costs and allows easy implementation into existing systems. Non-contact measurement: Frequency range - in the C-band. HART or PROFIBUS PA respectively FOUNDATION Fieldbus protocol. High temperatures:

Micropilot FMR50  Level measurement in liquids         Your benefits    Reliable measurement even for changing product and process conditions    Integrated data memory for high availability    Intuitive operating menu in national languages for easy commissioning    Simple integration into control or asset management systems    Exact diagnostic and process information to assist fast decisions    International approvals for use in hazardous areas    5-point linearity protocol Endress Hauser, National Language, Temperature Measurement, Asset Management, Languages, Menu, Simple, Easy, Idioms

Flow, level, liquid analysis, pressure, temperature measurement, software and system products

Micropilot FMR50 Level measurement in liquids Your benefits Reliable measurement even for changing product and process conditions Integrated data memory for high availability Intuitive operating menu in national languages for easy commissioning Simple integration into control or asset management systems Exact diagnostic and process information to assist fast decisions International approvals for use in hazardous areas 5-point linearity protocol

Changes at Endress+Hauser - Matthias Altendorf takes up his new position as CEO of the Group in January Endress Hauser, Process Engineering, January, Canada, Change, Group

Endress+Hauser

Matthias Altendorf takes up his new position as CEO of the Group in January – Klaus Endress joins the Supervisory Board

Micropilot M FMR231  Continuous and non-contact level measurement. Benefits: 2-wire technology, alternative to differential pressure, floats and displacers. 2-wire technology reduces wiring costs and allows easy implementation into existing systems.  Non-contact measurement:  Frequency range - in the C-band.   HART or PROFIBUS PA respectively FOUNDATION Fieldbus protocol.   Rod antenna with inactive length:  Reliable measurement in narrow nozzles, with condensation and build-up in the… Endress Hauser, Temperature Measurement, Foundation, Alternative, Wire, Range, Technology, Easy, Tech

Flow, level, liquid analysis, pressure, temperature measurement, software and system products

Micropilot M FMR231 Continuous and non-contact level measurement. Benefits: 2-wire technology, alternative to differential pressure, floats and displacers. 2-wire technology reduces wiring costs and allows easy implementation into existing systems. Non-contact measurement: Frequency range - in the C-band. HART or PROFIBUS PA respectively FOUNDATION Fieldbus protocol. Rod antenna with inactive length: Reliable measurement in narrow nozzles, with condensation and build-up in the…

Micropilot M FMR240  Continuous and non-contact level measurement.  4 to 20 mA 2-wire technology. Suitable for hazardous locations.  Benefits:  2-wire technology, alternative to differential pressure, floats and displacers.  2-wire technology reduces wiring costs and allows easy implementation into existing systems.   Non-contact measurement:  Frequency range - in the K-band.   HART or PROFIBUS PA respectively FOUNDATION Fieldbus protocol. Endress Hauser, Temperature Measurement, Flow, Foundation, Alternative, Wire, Range, Technology, Easy

Flow, level, liquid analysis, pressure, temperature measurement, software and system products

Micropilot M FMR240 Continuous and non-contact level measurement. 4 to 20 mA 2-wire technology. Suitable for hazardous locations. Benefits: 2-wire technology, alternative to differential pressure, floats and displacers. 2-wire technology reduces wiring costs and allows easy implementation into existing systems. Non-contact measurement: Frequency range - in the K-band. HART or PROFIBUS PA respectively FOUNDATION Fieldbus protocol.

Micropilot FMR53  Level measurement in liquids         Your benefits    Reliable measurement even for changing product and process conditions    Integrated data memory for high availability    Intuitive operating menu in national languages for easy commissioning    Simple integration into control or asset management systems    Exact diagnostic and process information to assist fast decisions    International approvals for use in hazardous areas    5-point linearity protocol Endress Hauser, National Language, Temperature Measurement, Asset Management, Languages, Flow, Menu, Simple, Easy

Flow, level, liquid analysis, pressure, temperature measurement, software and system products

Micropilot FMR53 Level measurement in liquids Your benefits Reliable measurement even for changing product and process conditions Integrated data memory for high availability Intuitive operating menu in national languages for easy commissioning Simple integration into control or asset management systems Exact diagnostic and process information to assist fast decisions International approvals for use in hazardous areas 5-point linearity protocol